Bright annealed Electrolytic Copper Conductors-insulated with delton PVC Compound as per BS 6746, IS 5831 Suitable for wiring panels for power, switches, instruments, control equipment, rectifier equipment, motor starters and controllers, building wiring, factory wiring, lighting and power connections for 250/440 volts and 650/1100 volts. Manufactured to standard specifications IS 694, BS 2004, BS 6004, BS 6261 and to derived delton specifications. |
|
|
Conductor size |
Nearest |
Current Rating |
Overall Diameter (Nom)(mm) |
( mm ) |
SWG |
( Amps ) |
250/440 Volts |
650/1100 Volts |
1/1.12 |
1/18 |
10 |
3.0 |
3.5 |
3/0.71 |
3/22 |
12 |
3.5 |
4.0 |
3/0.90 |
3/20 |
16 |
3.9 |
4.4 |
7/0.71 |
7/22 |
19 |
4.1 |
4.6 |
7/0.90 |
7/20 |
26 |
4.9 |
5.4 |
7/1.12 |
7/18 |
33 |
5.5 |
6.0 |
7/1.63 |
7/16 |
52 |
7.0 |
7.5 |
|
|
uctor Size |
Conductor Area |
Current Rating |
Suitable for voltage upto 1100 Volts |
( mm ) |
( mm² ) |
( Amps ) |
Insulation Thickness
(Nom)(mm) |
Overall Diameter
(Nom)(mm) |
1/1.38 |
1.5 |
14 |
0.7 |
2.9 |
1/1.78 |
2.5 |
18 |
0.8 |
3.5 |
1/2.25 |
4.0 |
24 |
0.8 |
4.0 |
1/2.76 |
6.0 |
31 |
0.8 |
4.5 |
7/1.35 |
10.0 |
42 |
1.0 |
6.2 |
7/1.70 |
16.0 |
57 |
1.0 |
7.3 |
7/2.14 |
25.0 |
73 |
1.2 |
8.9 |
7/2.52 |
35.0 |
90 |
1.2 |
10.1 |
19/1.78 |
50.0 |
145 |
1.4 |
11.9 |
19/2.14 |
70.0 |
185 |
1.4 |
13.7 |
|
Current ratings are applicable for Cables in Conduits and for an ambient temparature of 30° C. Other Conductor sizes in desired insulation thickness are manufactured as per customer needs. Supply of all Cables for Panel Wiring is Subject to provisions of Copper Control Order. |
|
| These are manufactured as per Indian JSS-548052 or US MIL-I-22129 or customer's requirements, Inside surface is smooth and free from irregularities. Available in solid electronics colours. |
|
| |
|
Bore mm |
Wall Thickness |
Overall Dia |
Bore |
Wall Thickness |
Overall Dia |
( Ncm) |
mm(Ncm) |
mm(Ncm) |
mm(Ncm) |
mm(Ncm) |
mm(Ncm) |
0.50 |
0.25 |
1.00 |
3.0 |
0.50 |
4.5 |
0.75 |
0.25 |
1.25 |
4.0 |
0.50 |
5.0 |
1.00 |
0.30 |
1.60 |
5.0 |
0.50 |
6.0 |
1.50 |
0.30 |
2.10 |
6.0 |
0.50 |
7.0 |
1.50 |
0.40 |
2.30 |
7.0 |
0.50 |
8.0 |
2.00 |
0.30 |
2.60 |
8.0 |
0.50 |
9.0 |
2.00 |
0.40 |
2.80 |
9.0 |
0.50 |
10.0 |
2.50 |
0.40 |
3.30 |
10.0 |
0.50 |
11.0 |
3.00 |
0.40 |
3.80 |
12.0 |
1.00 |
14.0 |
|
| |
|
This is also available in different widths ( cut piece or fresh ) to avoid the leakage in mechanical system as pipes, oil, gas from absolute vacuum to several thousand pressure, nontoxic, no contaminating and carrying any chemical or solvent. |
Beside above we also manufacture compensating cables and thermocouples cables on the specific requirements of customers. |
|
Colour : Standard colours of insulation Black, Red, Blue, Gray, Yellow and White. |
| Packing : In 91.4 Mtrs ( 100 Yds ) / 100 mtrs. coils. |
| Flostar insulation adds significantly to the tensile strength of the insulated conductor through the mechanism of load transfer because the insulation has such a superior break strength. |
|
| Insulation meterial depends upon the electrical and mechanical properies desired and the environments. The most common material are polyethylene and PVC. |
|
| |
| |